Winters here are mild but they're long enough to matter
Union County runs heat five months a year and the overnight low averages 33°F across the worst of it. That average is doing a lot of talking: it sits right at the two marks that matter for a heat pump. Below 40°F a standard heat pump puts out less than its rated capacity. Below about 35°F it typically needs backup heat to keep up. At 33°F average, this county lives on the wrong side of both marks all winter.
That doesn't mean it struggles every night. About 75 nights a year here fall at or below freezing, roughly half the nights the heat even runs. The other half stay above freezing, where a heat pump works the way it's rated to. And of those 75 cold nights, almost none reach 0°F. This is a county of a lot of mild-cold nights and almost no hard-cold ones.
That's the gap a cold climate heat pump is built to close. To earn the ENERGY STAR Cold Climate label, a heat pump has to deliver at least 1.75 units of heat per unit of electricity at 5°F, and hold onto 70 percent of its 47°F capacity at that same temperature, checked by outside testing. Union County's coldest nights almost never get near 5°F, so a cold climate model has room to spare here. A standard heat pump built to the federal minimum does not carry that same margin, which is why it leans on backup heat once the night drops toward freezing.
Field testing on prototype cold climate heat pumps backs this up in practice, not just on paper. Over two winters in occupied homes, backup heat covered only a small share of the total heat made between 0°F and 35°F, and running on backup alone was rare even above 0°F. Union County's winter lives almost entirely in that 0°F to 35°F band. A cold climate heat pump sized right for this house should be doing nearly all the work on its own, on nearly every night this county sees.