Can a heat pump keep up on a cold night here
Winter here is not severe. The heat runs five months, November through March, and the overnight low averages 34°F across December, January and February. It drops to freezing or below about 60 nights a year, and fewer than one night a year sees 0°F. That is the climate a heat pump has to handle in Anderson County.
A standard heat pump starts losing its edge below 40°F and often needs backup heat below about 35°F. The average winter low here sits below both marks, and every one of those 60 freezing nights does too. So on a typical cold night, a basic heat pump is working below its rated capacity, and on the coldest nights it is leaning on backup heat to make up the difference.
That is less of a problem than it sounds. Field testing on cold-climate heat pumps found backup heat covered only a small share of the heat needed between 0°F and 35°F, and running on backup alone was rare even above 0°F. Anderson County almost never sees 0°F. A heat pump built to the ENERGY STAR Cold Climate spec, which has to hold 70 percent of its 47°F capacity and still produce 1.75 units of heat per unit of electricity at 5°F, is built for weather colder than this county sees most winters. For a county where the average low stays at 34°F and real cold snaps are rare, that is more capacity than the climate demands.