What winter here actually asks of a heat pump
Heat runs seven months a year in Greenville County, October through April, so this is mostly a heating decision. The overnight low averages 34°F across December, January and February. That number matters because a standard heat pump has two weak points, and 34°F sits past both of them. Below 40°F its heat output falls short of what it's rated for. Below about 35°F it often needs backup heat to make up the difference. The average winter night here is past both marks, not just close to them.
That doesn't mean the heat pump struggles all winter. It means the coldest nights are the ones to look at, and here those nights are rarely severe. About 55 nights a year drop to 32°F or below, under a third of the roughly 210 nights the heat runs. Of those 55, fewer than one a year reaches 0°F. So the backup heat built into a heat pump here is covering a few dozen cold nights, not a season of deep freeze. In a two-winter field test of cold-climate heat pumps in occupied homes, backup heat supplied only a small share of the total heat between 0°F and 35°F, and running on backup alone was rare even above 0°F. A cold-climate heat pump, certified to keep most of its capacity at 5°F, has even less reason to lean on backup heat in a county that almost never sees that temperature.
A gas furnace doesn't have this problem. It burns gas and makes the same heat at 34°F as at any colder night, so the case for a furnace here is about that simplicity, not about the heat pump failing to keep up.