A white Southern-style house with a wraparound porch photographed at night, surrounded by Spanish moss-draped oak trees lit by landscape lights.

Heat Pump Installation in Greenville, SC

Tell us about the job

Takes about a minute. No obligation.

New system or replacementHeat PumpGreenville County, SC
Step 1 of 2

What ZIP code is the job in?

The rating is measured in a lab, not your house

The efficiency number on a heat pump comes from testing at set conditions, not from the home it ends up in. It tells you how one unit compares to another, not what it will cost to run. Ductwork, insulation, and how well the system was sized for the space all change the outcome as much as the rating does.

A higher rating usually means a different kind of compressor

Heat pumps with a higher rating often run a variable-speed or multi-stage compressor instead of a single-speed one, so they run longer at a lower output rather than switching on and off at full power. That gives steadier temperatures and less noise, but there's more inside the unit that can need service later. Ask what compressor is in the equipment, not just what the sticker says.

7 months
October through April, your system heats
5 months
May through September, it cools
34°F
the average winter night it heats against
87°F
the average summer afternoon it cools against
Isometric cutaway illustration of a single-story house showing interior ductwork, an air handler and rooms, with an outdoor condenser unit connected by refrigerant lines on a plain white background.
Your system heats October through April and cools May through September.

NOAA nClimDiv, 1991–2020 normals

Heat pumps in Greenville County run heat from October through April, seven months of the year.

September is the month to replace one, before it has to carry the first cold night.

Electricity here runs 14.23 cents a kilowatt-hour, cheaper than most of the country, so a high-efficiency heat pump pays back slowly here

Power costs 14.23 cents a kWh statewide
122 damaging wind events from 2015 to 2024
78 hail events from 2015 to 2024
A standard heat pump fits this climateZone 3A has a long mild season and a short winter, so a right sized standard system does the job here.

Electricity heats 56.9% of the homes in Greenville County, more than any other fuel. Utility gas comes next at 38.4%, with propane and oil making up the rest. If your house already runs on electric heat, a heat pump fits the wiring and layout that are already there. If it's gas, a contractor can still pair a heat pump with the existing ductwork, often keeping the furnace as backup for the coldest nights. Either way, telling the contractor what your house heats with now is the first thing that shapes the job.

Any new heat pump here has to meet 14.3 SEER2 and 7.5 HSPF2

Zone 3A's rules set the floor. Equipment installed in Greenville County now has to clear 14.3 SEER2 for cooling and 7.5 HSPF2 for heating, and a federal tax credit is available on top of that. A contractor can walk you through what qualifies.

Find a contractor
A residential heat pump outdoor unit mounted on a concrete pad next to a house with gray vinyl siding.

The size comes from the house, not the old unit

Sizing a heat pump starts with a load calculation, not the size of the unit coming out. That calculation looks at how much heat the house loses in winter and gains in summer, room by room, based on window area, insulation, ceiling height, and how the rooms connect to each other. Houses that look alike from the street can still need different sized equipment, because one has more west facing glass or a bonus room over the garage. A unit sized too big cools or heats the space fast, then shuts off, then kicks on again soon after. That short cycling keeps the compressor starting and stopping instead of settling into a long steady run, and starts are what wear a compressor down. A unit sized too small never gets that rest either. It runs long stretches trying to close the gap on the hardest days, and the house still ends up warmer or colder than the thermostat says. Ductwork factors into the sizing too. A correctly sized heat pump pushing air through ducts that are too small or too leaky still leaves rooms uneven, so the sizing has to account for what is actually moving the air, not just the unit bolted to the pad outside.

Ask what happens below freezing

Every heat pump loses some capacity as the outdoor temperature drops, and most lean on backup heat strips or a paired furnace to cover the gap on the coldest nights. Ask where that crossover point is for the equipment being quoted, and what kicks in when the heat pump alone can't keep up.

Get the load calculation, not a guess

The right size for your house comes from a room by room load calculation that accounts for windows, insulation, and layout, not a quick look at the old equipment's nameplate. If a contractor quotes a size without measuring the house, ask them to run the numbers before you sign.

The old furnace or AC does not just get hauled off and forgotten. A contractor recovers the refrigerant from the old outdoor unit before cutting any lines open, because venting it to the air is against the law and bad practice both. The indoor coil, the outdoor unit, and the old furnace if one is coming out all get disconnected and carried out, usually the same day the new equipment goes in. Copper lines get checked too. If they are sized right for the new system they sometimes get reused, but a heat pump often needs different line sizing than what was there before, so don't be surprised if the old lines come out along with everything else. Ask the contractor what they do with the old equipment and whether anything is salvaged or recycled, since practices vary.

The crew disconnects the old equipment first, then sets the new outdoor unit level on its pad. That matters because an unlevel pad makes the compressor wear unevenly over years of running. Line sets get run or reused and the connections get brazed. Before any refrigerant goes in, the system gets pulled down to a vacuum, and that step matters more than it looks. Moisture or air left in the lines causes problems later that are hard to trace back to the install. Once the refrigerant is charged and the thermostat is wired in, the contractor runs the system through both a heating cycle and a cooling cycle and checks the temperature at the vents before calling the job done.